{"created":"2023-06-19T11:22:28.131385+00:00","id":79,"links":{},"metadata":{"_buckets":{"deposit":"54a5ba64-517e-4f2e-90a7-50e6f6f608df"},"_deposit":{"created_by":12,"id":"79","owners":[12],"pid":{"revision_id":0,"type":"depid","value":"79"},"status":"published"},"_oai":{"id":"oai:jichi-ir.repo.nii.ac.jp:00000079","sets":["14:18"]},"author_link":["557","558","559","560"],"item_2_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2014-03","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"134","bibliographicPageStart":"129","bibliographicVolumeNumber":"36","bibliographic_titles":[{"bibliographic_title":"自治医科大学紀要"},{"bibliographic_title":"Jichi Medical University Journal","bibliographic_titleLang":"en"}]}]},"item_2_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"【目的】救急隊は少人数の活動である事,狭い家屋などの環境要因により,心肺蘇生の質を保つ事が困難である。そこで,自動心肺蘇生装置(AutoPulse®)の有用性を検証した。【対象と方法】救急車にAutoPulse®を配備して,2009年8月から2010年4月まで使用した。対照として,2008年度心肺停止症例を用い後ろ向きに検証した。\n【結果】AutoPulse®群14例,非AutoPulse®群25例。AutoPulse®群は,目撃なし,bystanderなしの症例が多く,初期波形asystoleが92.9%を占めたが,予後は心拍再開率42.9%,24時間生存率14.3%,社会復帰率7.1%で,非AutoPulse®群と有意な差を認めなかった。また,AutoPulse®群は,現場滞在時間が約1分短縮されていた。1例の社会復帰症例は,目撃あり,bystanderなし,初期波形asystoleの症例で,心拍再開まで32分を要したが社会復帰できた。\n【まとめ】病院前蘇生におけるAutoPulse®の使用は,救急隊の負担軽減,現場滞在時間の短縮につながる。また,質を保った絶え間ない胸骨圧迫が可能となり,心拍再開率,社会復帰率の増加が期待される。","subitem_description_type":"Abstract"}]},"item_2_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"自治医科大学"}]},"item_2_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1881-252X","subitem_source_identifier_type":"PISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"八坂, 剛一","creatorNameLang":"ja"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"山岸, 利暢","creatorNameLang":"ja"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"田村, 洋行","creatorNameLang":"ja"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"藤原, 俊文","creatorNameLang":"ja"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2014-05-29"}],"displaytype":"detail","filename":"p129-134.pdf","filesize":[{"value":"945.5 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"D:\\第36巻Web\\jichi medical 36\\36pdf-link\\p129-134.pdf","url":"https://jichi-ir.repo.nii.ac.jp/record/79/files/p129-134.pdf"},"version_id":"e1dcfd8c-779b-49e3-9b25-820a3ee0c148"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"病院前蘇生","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"心肺蘇生","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"胸音圧迫","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"自動心肺蘇生装置","subitem_subject_language":"ja","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"病院前蘇生における自動心肺蘇生装置(AutoPulse®)の有用性の検証","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"病院前蘇生における自動心肺蘇生装置(AutoPulse®)の有用性の検証","subitem_title_language":"ja"}]},"item_type_id":"2","owner":"12","path":["18"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2014-05-29"},"publish_date":"2014-05-29","publish_status":"0","recid":"79","relation_version_is_last":true,"title":["病院前蘇生における自動心肺蘇生装置(AutoPulse®)の有用性の検証"],"weko_creator_id":"12","weko_shared_id":-1},"updated":"2023-08-25T06:11:13.017323+00:00"}