{"created":"2023-06-19T11:22:44.754311+00:00","id":678,"links":{},"metadata":{"_buckets":{"deposit":"545ff4a3-1aaa-4296-8665-7fab9d2920c6"},"_deposit":{"created_by":12,"id":"678","owners":[12],"pid":{"revision_id":0,"type":"depid","value":"678"},"status":"published"},"_oai":{"id":"oai:jichi-ir.repo.nii.ac.jp:00000678","sets":["14:32"]},"author_link":[],"item_2_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"急性大動脈解離手術時に使用したGRF 糊が原因と考えられる遠隔期基部大動脈仮性瘤の一例","subitem_alternative_title_language":"ja"}]},"item_2_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2002-12","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"108","bibliographicPageStart":"103","bibliographicVolumeNumber":"30","bibliographic_titles":[{"bibliographic_title":"自治医科大学紀要"},{"bibliographic_title":"Jichi Medical University Journal","bibliographic_titleLang":"en"}]}]},"item_2_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"It has recently been reported that tissue toxicity from formaldehyde can cause a false\naneurysm around the aortic root in cases where GRF glue has been used. A residual \nascending aorta in a 55-year-old male became a very large false aneurysm during follow\nup after an acute type A aortic dissection. \nAt the initial operation, the ascending aorta had been replaced with a prosthetic graft\nand the anastomosis site repaired using gelatin resorcinol formaldehyde (GRF) glue.\n During the operation, necrosis of the arterial wall was\nrecognized around the proximal anastomosis site between the graft and the native aorta\nwall. Because of severe adhesion around the native aortic tissue and the left main \ncoronary artery the patient required an aorto-coronary bypass graft and an additional\npatch reconstruction of the pulmonary artery. \nThough the operation was very invasive because of the long cardiopulmonary bypass and\nanoxic arrest, the postoperative course was uneventful.\nThis report highlighted that careful follow up of a false aneurysm formation around an\naortic root is needed in cases where GRF glue is used in the initial operation. Surgeons\nneed to be aware of the distinctive complications possible in re-do operations around an\naortic root, and take steps to prevent such occurrences.","subitem_description_type":"Abstract"}]},"item_2_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"names":[{"name":"坂野, 康人","nameLang":"ja"}]},{"names":[{"name":"齊藤, 力","nameLang":"ja"}]},{"names":[{"name":"三澤, 吉雄","nameLang":"ja"}]}]},"item_2_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"自治医科大学"}]},"item_2_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1881-252X","subitem_source_identifier_type":"PISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Sakano, Yasuhito","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Saito, Tsutomu","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Misawa, Yoshio","creatorNameLang":"en"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-08-13"}],"displaytype":"detail","filename":"自治医科大学紀要1881-252X(30)p103-108.pdf","filesize":[{"value":"1.4 MB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"自治医科大学紀要1881-252X(30)p103-108","url":"https://jichi-ir.repo.nii.ac.jp/record/678/files/自治医科大学紀要1881-252X(30)p103-108.pdf"},"version_id":"1e0ea9ce-cbea-4903-b135-5f25c62d5a3c"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"仮性大動脈瘤","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"大動脈基部置換 術","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"A型急性大動脈解離","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"再手術","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"GRF 糊","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"False aneurysm","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Aortic root replacement","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Type A dissection, re-do","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"GRF (gelatin resorcinol-formaldehyde)","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Aortic root false aneurysm from gelatin-resorcinolformaldehyde( GRF) glue following surgical treatment for type A dissection","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Aortic root false aneurysm from gelatin-resorcinolformaldehyde( GRF) glue following surgical treatment for type A dissection","subitem_title_language":"en"}]},"item_type_id":"2","owner":"12","path":["32"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2019-08-13"},"publish_date":"2019-08-13","publish_status":"0","recid":"678","relation_version_is_last":true,"title":["Aortic root false aneurysm from gelatin-resorcinolformaldehyde( GRF) glue following surgical treatment for type A dissection"],"weko_creator_id":"12","weko_shared_id":-1},"updated":"2023-08-25T06:07:47.735224+00:00"}